VSAN Configuration and Management (MDS 9000 family)

Creating VSANs Statically

Step 1 switch# config t

Step 2 switch(config)# vsan database

switch(config-vsan-db)#

Step 3 switch(config-vsan-db)# vsan 2

Step 4 switch(config-vsan-db)# vsan 2 name TechDoc

updated vsan 2

Step 5 switch(config-vsan-db)# vsan 2 suspend

Step 6 switch(config-vsan-db)# no vsan 2 suspend

Step 7 switch(config-vsan-db)# end

switch#

Assigning Static Port VSAN Membership

Step 1 switch# config t.

Step 2 switch(config)# vsan database

switch(config-vsan-db)#

Step 3 switch(config-vsan-db)# vsan 2

Step 4 switch(config-vsan-db)# vsan 2 interface fc1/8

Step 5 switch(config-vsan-db)# vsan 7

Step 6 switch(config-vsan-db)# vsan 7 interface fc1/8

switch(config-vsan-db)# no vsan 7 interface fc1/8

Displaying VSAN Static Membership

switch # show vsan 1 membership

vsan 1 interfaces:

fc1/1 fc1/2 fc1/3 fc1/4 fc1/5 fc1/6 fc1/7 fc1/9

fc1/10 fc1/11 fc1/12 fc1/13 fc1/14 fc1/15 fc1/16 port-channel 99

switch # show vsan membership

vsan 1 interfaces:

fc2/16 fc2/15 fc2/14 fc2/13 fc2/12 fc2/11 fc2/10 fc2/9

fc2/8 fc2/7 fc2/6 fc2/5 fc2/4 fc2/3 fc2/2 fc2/1

fc1/16 fc1/15 fc1/14 fc1/13 fc1/12 fc1/11 fc1/10 fc1/9

fc1/7 fc1/6 fc1/5 fc1/4 fc1/3 fc1/2 fc1/1

vsan 2 interfaces:

fc1/8

vsan 7 interfaces:vsan 100 interfaces:

vsan 4094(isolated vsan) interfaces:

switch # show vsan membership interface fc1/1

fc1/1

vsan:1

allowed list:1-4093

Deleting Static VSANs

Step 1 switch# config t Enters configuration mode.

Step 2 switch(config)# vsan database

switch(config-db)#

Step 3 switch-config-db# vsan 2

switch(config-vsan-db)#

Step 4

switch(config-vsan-db)# no vsan 5

switch(config-vsan-db)#

Step 5 switch(config-vsan-db)# end

switch#

Configuring Load Balancing

Step 1 switch# config t

Step 2 switch(config)# vsan database

switch(config-vsan-db)#

Step 3 switch(config-vsan-db)# vsan 2

Step 4 switch(config-vsan-db)# vsan 2 loadbalancing src-dst-id

switch(config-vsan-db)# no vsan 2 loadbalancing src-dst-id

switch(config-vsan-db)# vsan 2 loadbalancing src-dst-ox-id

 

Step 5 switch(config-vsan-db)# vsan 2 suspend

Step 6 switch(config-vsan-db)# no vsan 2 suspend

Step 7 switch(config-vsan-db)# end

switch#